Dome Classic Systems

  • Is suitable for nearly all types of flat roofs. It is very easy to install using fewer K2 System components
  • A system for statically difficult roofs and special applications
  • Can also be mounted on ­trapezoidal sheet metal roofs
  • Quick and easy handling

Lightning protection and equipotential bonding

With the help of our TerraGrif U17 or K2SZ, simple and quick module­­frame­­groundings can be made for Dome systems. Our lightning protection clamp set can be placed directly. Aluminium cables for lightning protection are thus connected directly.

 

 

 

1/4 clamping with FlexClamp

1/4 clamping with FlexClamp

With the K2 FlexClamp, the D-Dome Classic system can also be used for high wind and snow loads or large modules. In combination with the K2 FlexClamp, the system is approved for snow loads up to 4 kN/m² and wind loads up to 1.3 kN/m².

 

Single-sided elevation with S-dome

Single-sided elevation with S-Dome

The windbreaker is required for the S-Dome elevation - for example towards the south. This is attached to the back and is available in different lengths for different modules.

 

 

 

Mounted on trapezoidal sheet metal roofs

Mounted on trapezoidal sheet metal roofs

The Dome systems can also be mounted on trapezoidal sheet metal roofs. This is possible with the SpeedClip from the SpeedRail system and is mounted similarly.

References

Components

Downloads

Available in the respective languages  

Product data sheet and Brochure

Assembly instructions and Checklist

Tender specifications and certificates

Document type
Tender specification  D-Dome
Tender specification  S-Dome
Certificate Structural Analyses  D-Dome
Certificate Structural Analyses  S-Dome
Expert's report wind loads  D-Dome
Expert's report wind loads  S-Dome

Videos

Approved modules

Here you find a list of modules which are approved for our Dome flat roof systems.

 

Technical data

 
D-Dome
S-Dome
Scope of application

Flat roofs ≤ 5° with single ply membrane or bituminous roof covering, also on concrete, gravelled or green roofs; also trapezoidal sheet metal roofs with continuous mounting rails

Fastening type / roof fixture

Ballasted; no roof penetration for inclination ≤ 3°

Requirements

  • Permissible module dimensions (L × W × H): 1386-2300 × 950-1100 × 30-50mm
  • Minimum system size: 2 supports (4 modules)
  • Module approved for corner clamping (see approved modules…)

  • Permissible module dimensions (L × W × H): 1386-2067 × 950-1100 × 30-50mm
  • Minimum system size: 2 modules
  • Module approved for corner clamping (see approved modules…)
Technical specifications

  • Thermal separation after max. 11m (trapezoidal sheet metal 8.8m)
  • Minimum clearance to roof edge 600 mm
Inclination angle

10°

Material

  • Mounting rails, D-Dome, Dome SD, Module Clamps, Rail Connectors: Aluminium EN AW-6063 T66
  • Building protection mat with or without aluminium lining (PUR-bound rubber granules)
  • Small parts: Stainless steel (1.4301) A2-70

  • Mounting rails, S-Dome, Dome SD, Windbreaker, module clamps, rail connectors: Aluminium EN AW-6063 T66
  • Building protection mat with or without aluminium lining (PUR-bound rubber granules)
  • Small parts: Stainless steel (1.4301) A2-70
D-Dome
Scope of application

Flat roofs ≤ 5° with single ply membrane or bituminous roof covering, also on concrete, gravelled or green roofs; also trapezoidal sheet metal roofs with continuous mounting rails

Fastening type / roof fixture

Ballasted; no roof penetration for inclination ≤ 3°

Requirements

  • Permissible module dimensions (L × W × H): 1386-2300 × 950-1100 × 30-50mm
  • Minimum system size: 2 supports (4 modules)
  • Module approved for corner clamping (see approved modules…)
Technical specifications

  • Thermal separation after max. 11m (trapezoidal sheet metal 8.8m)
  • Minimum clearance to roof edge 600 mm
Inclination angle

10°

Material

  • Mounting rails, D-Dome, Dome SD, Module Clamps, Rail Connectors: Aluminium EN AW-6063 T66
  • Building protection mat with or without aluminium lining (PUR-bound rubber granules)
  • Small parts: Stainless steel (1.4301) A2-70
S-Dome
Scope of application

Flat roofs ≤ 5° with single ply membrane or bituminous roof covering, also on concrete, gravelled or green roofs; also trapezoidal sheet metal roofs with continuous mounting rails

Fastening type / roof fixture

Ballasted; no roof penetration for inclination ≤ 3°

Requirements

  • Permissible module dimensions (L × W × H): 1386-2067 × 950-1100 × 30-50mm
  • Minimum system size: 2 modules
  • Module approved for corner clamping (see approved modules…)
Technical specifications

  • Thermal separation after max. 11m (trapezoidal sheet metal 8.8m)
  • Minimum clearance to roof edge 600 mm
Inclination angle

10°

Material

  • Mounting rails, S-Dome, Dome SD, Windbreaker, module clamps, rail connectors: Aluminium EN AW-6063 T66
  • Building protection mat with or without aluminium lining (PUR-bound rubber granules)
  • Small parts: Stainless steel (1.4301) A2-70

Side views

D-Dome
D-Dome
S-Dome
S-Dome