Dome Classic Systems

    • Is suitable for nearly all types of flat roofs. It is very easy to install using fewer K2 System components
    • A system for statically difficult roofs and special applications
    • Can also be mounted on ­trapezoidal sheet metal roofs
    • Quick and easy handling
    Dome Classic Properties

    Lightning protection and equipotential bonding

    With the help of our TerraGrif U17 or K2SZ, simple and quick module­­frame­­groundings can be made for Dome systems. Our lightning protection clamp set can be placed directly. Aluminium cables for lightning protection are thus connected directly.

     

     

     

    1/4 clamping with FlexClamp

    1/4 clamping with FlexClamp

    With the K2 FlexClamp, the D-Dome Classic system can also be used for high wind and snow loads or large modules. In combination with the K2 FlexClamp, the system is approved for snow loads up to 4 kN/m² and wind loads up to 1.3 kN/m².

     

    Single-sided elevation with S-dome

    Single-sided elevation with S-Dome

    The windbreaker is required for the S-Dome elevation - for example towards the south. This is attached to the back and is available in different lengths for different modules.

     

     

     

    Mounted on trapezoidal sheet metal roofs

    Mounted on trapezoidal sheet metal roofs

    The Dome systems can also be mounted on trapezoidal sheet metal roofs. This is possible with the SpeedClip from the SpeedRail system and is mounted similarly.

    References

    Components

    Downloads

    Available in the respective languages  

    Product data sheet and Brochure

    Document type
    Product­ data sheet  EN
    Product­ data sheet  PT
    Brochure Flat roof systems  EN
    Brochure Flat roof systems  PT
    Accessories Flat roof systems  EN
    Accessories Flat roof systems  PT

    Assembly instructions and Checklist

    Document type
    Assembly instructions  D-Dome Classic
    Assembly instructions  S-Dome Classic
    Assembly instructions  Trapezoidal sheet metal
    Checklist Flat roof systems  EN
    Checklist Flat roof systems  PT
    Recommendations for lightning protection and equipotential bonding  Flat roof systems

    Tender specifications and certificates

    Document type
    Tender specification  D-Dome
    Tender specification  S-Dome
    Certificate Structural Analyses  D-Dome
    Certificate Structural Analyses  S-Dome
    Expert's report wind loads  D-Dome
    Expert's report wind loads  S-Dome

    Videos

    Approved modules

    Here you find a list of modules which are approved for our Dome flat roof systems.

     

    Technical data

     
    D-Dome
    S-Dome
    Scope of application

    Flat roofs ≤ 5° with single ply membrane or bituminous roof covering, also on concrete, gravelled or green roofs; also trapezoidal sheet metal roofs with continuous mounting rails

    Fastening type / roof fixture

    Ballasted; no roof penetration for inclination ≤ 3°

    Requirements

    • Permissible module dimensions (L × W × H): 1386-2300 × 950-1100 × 30-50mm
    • Minimum system size: 2 supports (4 modules)
    • Module approved for corner clamping (see approved modules…)

    • Permissible module dimensions (L × W × H): 1386-2067 × 950-1100 × 30-50mm
    • Minimum system size: 2 modules
    • Module approved for corner clamping (see approved modules…)
    Technical specifications

    • Thermal separation after max. 12m (trapezoidal sheet metal 8.8m)
    • Minimum clearance to roof edge 600 mm
    Inclination angle

    10°

    Material

    • Mounting rails, D-Dome, Dome SD, Module Clamps, Rail Connectors: Aluminium EN AW-6063 T66
    • Building protection mat with or without aluminium lining (PUR-bound rubber granules)
    • Small parts: Stainless steel (1.4301) A2-70

    • Mounting rails, S-Dome, Dome SD, Windbreaker, module clamps, rail connectors: Aluminium EN AW-6063 T66
    • Building protection mat with or without aluminium lining (PUR-bound rubber granules)
    • Small parts: Stainless steel (1.4301) A2-70
    D-Dome
    Scope of application

    Flat roofs ≤ 5° with single ply membrane or bituminous roof covering, also on concrete, gravelled or green roofs; also trapezoidal sheet metal roofs with continuous mounting rails

    Fastening type / roof fixture

    Ballasted; no roof penetration for inclination ≤ 3°

    Requirements
    • Permissible module dimensions (L × W × H): 1386-2300 × 950-1100 × 30-50mm
    • Minimum system size: 2 supports (4 modules)
    • Module approved for corner clamping (see approved modules…)
    Technical specifications
    • Thermal separation after max. 12m (trapezoidal sheet metal 8.8m)
    • Minimum clearance to roof edge 600 mm
    Inclination angle

    10°

    Material
    • Mounting rails, D-Dome, Dome SD, Module Clamps, Rail Connectors: Aluminium EN AW-6063 T66
    • Building protection mat with or without aluminium lining (PUR-bound rubber granules)
    • Small parts: Stainless steel (1.4301) A2-70
    S-Dome
    Scope of application

    Flat roofs ≤ 5° with single ply membrane or bituminous roof covering, also on concrete, gravelled or green roofs; also trapezoidal sheet metal roofs with continuous mounting rails

    Fastening type / roof fixture

    Ballasted; no roof penetration for inclination ≤ 3°

    Requirements

    • Permissible module dimensions (L × W × H): 1386-2067 × 950-1100 × 30-50mm
    • Minimum system size: 2 modules
    • Module approved for corner clamping (see approved modules…)
    Technical specifications

    • Thermal separation after max. 12m (trapezoidal sheet metal 8.8m)
    • Minimum clearance to roof edge 600 mm
    Inclination angle

    10°

    Material

    • Mounting rails, S-Dome, Dome SD, Windbreaker, module clamps, rail connectors: Aluminium EN AW-6063 T66
    • Building protection mat with or without aluminium lining (PUR-bound rubber granules)
    • Small parts: Stainless steel (1.4301) A2-70

    Side views

    D-Dome
    D-Dome
    S-Dome